Series 65 Heat Detector

€25.00 ex VAT

The Series 65 Heat Detectors monitor temperature by using either a dual thermistor network or a single thermistor network (CS versions), providing a voltage output proportional to the external air temperature.

Category:

Description

Key Features

  • Ideal for environments that are dirty or smoky under normal circumstances
  • Suitable where smoke detectors are unsuitable
  • Wide operating voltage: 9 V to 33 V DC

Product Information

Supply wiring Two-wire monitored supply, polarity insensitive
Terminal functions L1 IN & L2 IN; L1 OUT & L2 OUT; –R remote indicator negative connection
Supply voltage 9 V to 33 V DC
Ripple voltage 2 V peak-to-peak max at 0.1 Hz to 100 kHz
Alarm voltage 6 V to 28 V DC
Alarm indicator Red light emitting diode
Design alarm load 420 Ω in series with a 2 V drop
Holding voltage / current 6 V / 10 mA
Remote output (–R) Current sink to negative line, limited to 17 mA
Storage temperature –30 °C to +80 °C
Operating temperature A1R: –20 °C to +50 °C;
BR: –20 °C to +65 °C;
CS/CR: –20 °C to +80 °C
Humidity 0 % to 95 % RH (no condensation or icing)
IP rating IP54
Dimensions Ø 100 mm × H 42 mm
Weight 80 g
Materials Housing: white flame-retardant polycarbonate; Terminals: nickel-plated stainless steel

Current Characteristics

Supply Voltage (V) Quiescent (A1R Std) Alarm (A1R Std) Quiescent (A1R LED) Alarm (A1R LED) Quiescent (A1R LED/Mag) Alarm (A1R LED/Mag)
24 45 µA 52 mA 55 µA 52 mA 55 µA 52 mA
9 40 µA 17 mA 50 µA 17 mA 50 µA 17 mA

Variants & Part Numbers

Class Max Application Temp (°C) Max Static Response Temp (°C) Part No. Standard Part No. Flashing LED
A1R 50 65 55000-122 55000-121
BR 65 85 55000-127 55000-126
CR 80 100 55000-132 55000-131
CS 80 100 55000-137 55000-136

Operation

In the A1R, BR and CR variants, paired NTC thermistors (one exposed, one insulated) sit on the PCB. Under stable conditions they have equal resistance; a rapid temperature rise causes the exposed thermistor’s resistance to drop relative to the insulated one. When the ratio exceeds a factory preset threshold, the detector alarms. CS variants use a single NTC thermistor network to provide a voltage output proportional to ambient temperature.

Compliance & Certification

  • EMC Directive 2014/30/EU
  • Construction Products Regulation (EU) 305/2011
  • CPR, LPCB, VdS, VNIIPO, SBSC, FG & BOMBA approvals*
  • ISO 9001:2015 & ISO 14001:2015 certified (LPCB ref. 010)

*Not all detectors carry every approval; see product pages for details.